INOX МО3 advanced 8” RO System

Ecosoft INOX MO3 is an advanced industrial reverse osmosis system equipped with IoT functionality. It can be used for water with TDS up to 4500 ppm and operates at a pressure of 15 bars. The pressure pipeline is made of AISI 316 stainless steel, which makes these systems highly reliable in operation. Ecosoft reverse osmosis […]

FEATURES

  • Online access to the RO machine
  • High pressure pipeline is made of AISI 316 stainless steel
  • Frame is made of AISI 304 stainless steel
  • Reliable and stable performance
  • Flexible flow adjustment for various feed water
  • Predesigned options for tailor-made solutions
  • Energy-efficient and global warranty thanks Grundfos® pump

HOW IT WORKS

TECHNICAL INFORMATION

Equipment

  • Grundfos® CR 10-12 high pressure pump — 1 pcs
  • 8040 membrane housing — 3 pcs
  • BB20 sediment prefilter — 3 pcs
  • Motorized valves (feed water in, flush out) — 2 pcs
  • Balancing valves (concentrate reject, concentrate recycle) — 2 pcs
  • Electrical panel with Ecosoft controller OC6000 — 1 set
  • Set of instruments — 1 set
  • AISI 316 Stainless steel high pressure line — 1 set
  • AISI 304 Stainless steel frame — 1 set
  • Frame mounted casters — 1 set

Options

  • Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
  • Dosing pump for antiscalant or other RO chemicals
  • Permeate inlet for permeate membrane rinse
  • Raw water mixing line

Сonnections

  • Influent water — G 1½″
  • Permeate — G 1″
  • Concentrate — G 1½″
  • CIP inlet — G 1½″
  • CIP return — G 1½″
  • CIP permeate — G ½″
  • Antiscalant dosing port — G ½″

Technical data

  • Permeate capacity¹ — 3 m³/h
  • Permeate recovery² — 75%
  • Maximum TDS — 4500 mg/L
  • Influent flow demand:
    – 4…6 m³/h (service)
    – 10 m³/h (rinse)
  • Operating pressure — 8…12 bar
  • Maximum pressure — 15 bar
  • Electrical requirements — 380…400 V, 50 Hz (3 ph)
  • Electrical power — 4 kW
  • Prefilter rating — 5 μm
    ¹ depends on feed water TDS, temperature, and permeate recovery
    ² for low scaling/fouling water

Feed water requirements

  • TDS — 4500 mg/L
  • hardness — 150 mg/L CaCO₃
  • iron — 0.1 mg/L
  • manganese — 0.05 mg/L
  • hydrogen sulfide — none
  • silicate — 20 mg/L
  • residual chlorine — 0.1 mg/L
  • SDI — 5
  • chemical oxygen demand – 4 mg/L O₂

 

Download Technical Data Sheet