МО3 8″ RO System

Ecosoft MO3 industrial reverse osmosis system is a turnkey solution for industrial water challenges, that includes pilot studies, engineering and manufacturing, commissioning and maintenance. Ecosoft reverse osmosis systems are used in food and pharmaceutical industry, energy, chemical, semiconductor manufacturing, steam boilers and other industrial applications.

FEATURES

  • Ecosoft OC5000 controller since 2008
  • Reliable and stable performance
  • Flexible flow adjustment for various feed water
  • Predesigned options for tailor-made solutions
  • Energy-efficient and global warranty thanks Grundfos® pump

HOW IT WORKS

TECHNICAL INFORMATION

Equipment

  • Grundfos® CR 10-12 high pressure pump — 1 pcs
  • 8040 membrane vessel — 3 pcs
  • BB20 sediment prefilter — 3 pcs
  • Motorized valves (feed water in, flush out) — 2 pcs
  • Balancing valves (concentrate reject, concentrate recycle) — 2 pcs
  • Electrical cabinet with Ecosoft controller — 1 set
  • Piping, instrumentation, steel frame — 1 set

Options

  • Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
  • Dosing pump for antiscalant or other RO chemicals
  • Permeate inlet for permeate membrane rinse
  • Raw water blending line

Сonnections

  • Influent water — 1½″
  • Permeate — 1″
  • Concentrate — 1½″
  • CIP inlet — 1½″
  • CIP return — 1½″
  • CIP permeate — ½″
  • Antiscalant dosing port — ½″

Technical data

  • Permeate capacity¹ — 3 m³/h
  • Permeate recovery² — 75%
  • Maximum TDS — 3000 mg/L
  • Influent flow demand:
    – 4…6 m³/h (service)
    – 10 m³/h (rinse)
  • Operating pressure — 8…12 bar
  • Maximum pressure — 14 bar
  • Electrical requirements — 380…400 V, 50 Hz (3 ph)
  • Electrical power — 4 kW
  • Prefilter rating — 5 μm
    ¹ depends on feed water TDS, temperature, and permeate recovery
    ² for low scaling/fouling water

Feed water requirements

  • TDS — 3000 mg/L
  • hardness — 150 mg/L CaCO₃
  • iron — 0.1 mg/L
  • manganese — 0.05 mg/L
  • hydrogen sulfide — none
  • silicate — 20 mg/L
  • residual chlorine — 0.1 mg/L
  • SDI — 5
  • chemical oxygen demand – 4 mg/L O₂

 

Download Technical Data Sheet